What happens if there is no nuetral in the power system?
Answer Posted / subash
electrical high load equipments are damages like motors, refrigerators,tv,etc....
| Is This Answer Correct ? | 1 Yes | 9 No |
Post New Answer View All Answers
Please elaborate th´evenin’s theorem?
what are the types of electromagnetic forces developed in practical transformer?
how to calculation increase capacitor,increase power factor for three phase.
What is difference between Over Current & Earth Fault protection?
why the name trunking bus PT
what are the application of over current relay?
In ups static switch if i gives the supply at output end it will open the circuit in stactic switch or not if it will open then how it operates.
What do you understand by oldham's coupling ?
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
why ahould you show client/engineer activities clearly on the project plan
why +24 v and -48 v give to BTS? If -48v protect from surge then why we not use -24 v?
how we test a 3 phase motor on single phase supply....? HOW WE RUN A 3 PHASE MOTOR ON SNIGLE PHASE. supply for testing..? how we verify of a 3 phase motors 6 wire & name thame a1/a2/a3..b1/b2/b3 and c1/c2/c3 for connecting star delta starter ........i have only 1 phase supply ? help forum..........
how make megger test for control cable like 12c x 1.5mm and what it apply voltage and test timing details.
I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
why is the conservator tank painted white on the transformer