Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

One 15kw motor Why we used star delta feeder?why not used DOL
please explain in details

Answer Posted / brd ganesh

We can use dol stater up to 5HP (dol stater can
not control starting current of motor but protect
by them up to 5HP). We have been using dol
staters to lower rating ac motors due to low cost.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

The sodium vapor lamp is not glows when it is connected a distance of 5 meters above from gearbox, why ?

3722


what is basic difference betmeen normal & flame proof motor??

2094


I had applied for JE in PSEB, Can you pls send me the Question bank for related to my field

1916


What are the advantages of vscf wind electrical system?

1140


how to calculate percentage impedence at 75 deg C at normal tap

2297


detailed procedure how we calculate cost for pcc m10 and rcc m20 including centering and labour excluding steel/ iron

3179


What is force on parallel conductors ?

1141


in wind mill use 2100 kw asychronous generator ( induction generator ) rotor voltage : 3300,stator voltage : 690, rpm : 1511 type : MRL063E04 ' we check rotor resistance magger value found following. R-EARTH - 00 M.OHM,Y-EARTH-34 M.OHM,B-EARTH- 33M.OHM R-Y: 31 M.OHM, Y-B: 00 M.OHM,B-R :33 M.OHM HOW CAN I TAKE DECISION?pls ans. quickly

2350


Importance of fault current in power transformers and how to monitor the same? How is it different from winding temperature?

1892


EXPLAIN THE TERMS "INTEREST AND DEPRECIATION" AS APPLIED TO ECONOMICS OF POWER GENERATION.

2380


in the case of 6.6kv motor starter combination contain fuses on it VCB. but in 11KV motor starter combination Fuses are not using in it's VCB why?

2344


why we dont prefer ac voltage controller instead dimmerstat [if both have same rating] for conducting experiments in laboratories?

2202


A d.c. Shunt motor is found suitable to drive fans because they require?

1390


What are the ratings of VCB, MCB, MCCB, SF6, ACB, and OCB?

1617


Why MCCB is Getting tripped sometimes when there is no load in the Midnight ?

2067