Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Is it possible to get earth resistance value"zero" Ohm
practically???
If yes,which type of earthing???

Answer Posted / shafi

It is desined by earthing calculation and practical
proved ,practical reading is taken in oil & gas area

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan

1671


What was your role in the silicon evaluation/product ramp? What tools did you use?

1952


how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets

2173


why the active power flow of some line is increased when the active power of out is cut ?

2038


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2209


The capacitive reactance of a capacitor of 1/(2(PI)) F at 10^3 H is

1839


how to get electrical supervisour certificate in gujarat

1951


WHY EXCITER PHASE SEQUENCE ARE OPPOSITE THAN STATOR SUPPLY PHASE SEQUENCE IN SYNCHRONOUS MOTOR >

1899


what is the difference between gas group b and gas group c electrical equipment construction wise?

1861


What will happen if the d.c. Machine is operated below rated speed?

1224


AL=0B9H,bl=75H, ADD AL,BL AL=____________? CF________? OF___________?

2665


HOW TO CALCULATE HV CABLE SIZING?

3208


Define thermal resistance in the context of power amplifier.

1119


what type of earthing do for dry fissure rock?

2429


What if the difference beween internal and exrteranal LBB?

1669