Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

1. what is 3 point calibration & 5 point calibration?
2. If we use hart communicator to set the LRV & URV of a
smart transmitter, did we calibrate the transmitter? why?
3. Make a complet list if meterials needed to properly
connect a pressure gauge to a steam pipe using 1/2 inch
stainless steel tubing. The gauge connections is 1/2 inch
NPT-M and the steam pipe tap has a 1/2 inch female coupling,
compression fittings are use.
4. What are the tools in loop checking?
5. What would the ISA symbol of a square root extractor look
like?
6. What would you do to completely prepare for the
configuration?
7. What safety measures must you undertake when doing
configuration?
8. what are the two most commonly use programming languages
used when we configure a PLC?
9. What would you do if you accidentally skipped a step in
the configuration procedure?
10. How would you know if the configuration were sucessful?
11. Name at least 3 selections available when we configure
the burnout protection of a controller?

Answer Posted / anand.r biocon limited

1. 3 & 5 point calibration

When calibrating the field instruments or device under test only 3 process reading compared with master instrument for 5 point calibration you should do comparison for 5 process values with master instrument

2. If we use hart communicator to set the LRV & URV of a
smart transmitter, did we calibrate the transmitter? why?

This is not calibration of transmitter we can say this is configuring BASIC parameters to the TX.

3. Make a complet list if meterials needed to properly
connect a pressure gauge to a steam pipe using 1/2 inch
stainless steel tubing. The gauge connections is 1/2 inch
NPT-M and the steam pipe tap has a 1/2 inch female coupling,
compression fittings are use.

By using sypon and 1/2 " nipple you can mount the pressure gauge on steam line if the line is vertical you should have 45 deg angle to the process line to reduce the pressure drop across the instrument.


8.. what are the two most commonly use programming languages
used when we configure a PLC?


Ladder logic
FBD- Functional block diagram

Is This Answer Correct ?    14 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How servomotor controls throttle valve of TURBINE?

2008


Why is the orifice tab provided?

1294


How oil line flow measured?eplain about instruments used and working principle?

2098


how can leve transmetter calibate in feild .and also put cv and flow plz .....

2291


How is flow measured in square root?

1343


Sir, I want junior executive, Instrumentation question papaer for IOCL, Plz send to arabinda.ghosh83@gmail.com

2379


how to calibrate 0- 150 psi presure gauge by dead weght tester

2111


why I need valve guard and whats different between guard and positioner ??

1425


Why we are using reverse action in displacer types level transmitters on some Vessels?

2601


Can anybody please let me know Orifice plate sizing calculation formula and step by step procedure

2031


Why flow/pressure transmitter before control valve?

1613


Emergency Shutdown Systems/ Plant Shutdown System.

2319


How to calibrate RC Feeder system in thermal power station?,If any instrument available to calibrate it,ple inform me. make:stock,

3235


How is work 5/2 sov?

1944


what is loop1 and loop2 in MTS LT?

4713