1. what is 3 point calibration & 5 point calibration?
2. If we use hart communicator to set the LRV & URV of a
smart transmitter, did we calibrate the transmitter? why?
3. Make a complet list if meterials needed to properly
connect a pressure gauge to a steam pipe using 1/2 inch
stainless steel tubing. The gauge connections is 1/2 inch
NPT-M and the steam pipe tap has a 1/2 inch female coupling,
compression fittings are use.
4. What are the tools in loop checking?
5. What would the ISA symbol of a square root extractor look
like?
6. What would you do to completely prepare for the
configuration?
7. What safety measures must you undertake when doing
configuration?
8. what are the two most commonly use programming languages
used when we configure a PLC?
9. What would you do if you accidentally skipped a step in
the configuration procedure?
10. How would you know if the configuration were sucessful?
11. Name at least 3 selections available when we configure
the burnout protection of a controller?

Answer Posted / anand.r biocon limited

1. 3 & 5 point calibration

When calibrating the field instruments or device under test only 3 process reading compared with master instrument for 5 point calibration you should do comparison for 5 process values with master instrument

2. If we use hart communicator to set the LRV & URV of a
smart transmitter, did we calibrate the transmitter? why?

This is not calibration of transmitter we can say this is configuring BASIC parameters to the TX.

3. Make a complet list if meterials needed to properly
connect a pressure gauge to a steam pipe using 1/2 inch
stainless steel tubing. The gauge connections is 1/2 inch
NPT-M and the steam pipe tap has a 1/2 inch female coupling,
compression fittings are use.

By using sypon and 1/2 " nipple you can mount the pressure gauge on steam line if the line is vertical you should have 45 deg angle to the process line to reduce the pressure drop across the instrument.


8.. what are the two most commonly use programming languages
used when we configure a PLC?


Ladder logic
FBD- Functional block diagram

Is This Answer Correct ?    14 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the purpose of bypass valve across AS valve.

1656


types of cable..? Use of every types of cable..?

1599


Area classification, Equipments, Gas groups, temperature classification, Ingress protection, Fire Extinguishers.

1499


What is the use of temprature compensation?

712


How to Calibrate Ultrasonic flow Transmitter in Field

794






If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?

1025


How to convert Differential pressure to flow in TPH

1749


For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?

5004


IS there any effect of vortex in low pressure side of the transmiter after the orific in feed water line? if yes then what is the calculation?

1941


What is furnace draft control?

634


HOW CREATED LP & HP PRESURES IN DRUM FOR DRUM LEVEL MEASUREMENT!

1432


components of control circuit belongs to control valve

1235


what is the vital subject for scoring bhel exam&what is the question pattern

1882


Why plc require in analog input 4-20amp & 0-10 volt?

625


god evening sir i am studying m.sc(tech)electronics &instrumention.am i elegible to all industies

1380