please explain clearly in PID controller if We increase P
only what will be action of the contrlere.
Answer Posted / carl_ellis
Any given amount of error will produce less output change
than before the proportional band was increased.
Increasing the proportional band will make the controller
less sensitive to the deviation of the process variable
(PV) from the setpoint (SP).
Tell 'em Carl sent you.
Is This Answer Correct ? | 2 Yes | 4 No |
Post New Answer View All Answers
Any one can help me to identified, how can we interchange the device in FF
How to calibrate Magnetic flow Transmitter in Field
How u measure the massflow in orifice flow measurement techniques
HOW TO CALCULATE ACCURACY OF AN INSTRUMENT. WHICH IS COMPITABLE FOR USE.
1. For Steam drum level signal, why do we compensate with drum pressure signal? 2.For main steam Flow signal is comensated with main steam temperature signal and main steam pressure signal why?
what is the difference between -24 : +24 & 0:24 and where it use?
What denotes the 5/8mm in the 3300XL 5/8mm proximitor probe?
flow transmeter accuracy 0.075% of full scale & find ucertainty is 0.025 % so what is maximum limit band of uncertainty
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
Specify ideal accuracy of flow element like orifice plate, Ventury, Annubar. Ultrasonic flow meter etc.
State some of balance principle’ advantages?
For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?
What is the use of double seated valve?
Hi, I am Newely Joined in Construction company instrument engineer? Any one can Plz tell me How can I advanced preparation for Releated Engineering and construction Documents?
how is work pressure switch& level switch?what is the principle of this?