Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why do 4 mA serves as 0% not 0 mA?

Answer Posted / abhishek rathore

4mamp current signal consider as 0% if sensor or wireing fault then signal goes to 0mamp controller or operator understand signal fault mode goes.1,2,3mA not consider because bydeafault 1-3% signal present in the systembut 4mA not goes to signal bydefault .so we are consider 4-20mA signal

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why is the orifice tab provided?

1193


We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1642


How oil line flow measured?eplain about instruments used and working principle?

2041


How the warning lamp of a charging-system is activated ?

2622


What is the use of each wire in three wire RTD

2486


Why grounding is necessary? Give example with diagram.

2193


Define cryogenic?

1146


Explain an adaptive / self-tuning controller’s major draw card.

2307


send me last 5 years questions asked in rrb chennai, for section engineer

2083


Who to difference between analog in & analog out in dcs?

1625


Hi Friends i need Electronics&Instrumentation Engg question papers for BARC written test by coming 20th May 2008 pls post ur use full info to kkumarei@gmail.com. Or for suggestions pls give one missed call to 9962122264

1939


Name different parts of a pressure gauge.

1100


what is 24vdc live and dry supply

2243


you are on site,the plant trips,you are approached by operations,what do you do?

2229


what is the process to make control schematic ?

2234