Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference b/w bus reactor and line reactor?

Answer Posted / arup chakraborty

BUS REACTOR:-(Electricity) An air-core inductor connected
between two buses or two sections of the same bus in order
to limit the effects of voltage transients on either bus.
Reduce fault current.Bus reactors a devise installed in a
bus to maintain system voltage when the load on the bus
changes by releasing reactive power as usable power to
bolster the voltage.
LINE REACTOR:- A line reactor is placed in line at point of
use or just after a transformer to maintain a stable
amperage to the user, capacitor.

Is This Answer Correct ?    12 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP

1937


Define the overload capacity of the motor?

2120


How to Design green buildings services? What is the advantage to design green building?

1855


What is a DC series motor?

1294


please explain how to do 'pole drop test' on generator?

2960


When lag/lead/lag-lead compensation is employed?

1247


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

1514


What is difference between insulating medium and fault current interruption medium in a switching device.

1711


How can find thermal state value in relay for calculate thermal overload.

1963


the problem faced on star or delta winding connection??

1976


What happen in ups if phase reverse?

2354


What is the formuala to calculate the rating of motor protection circuit breaker

2262


please send me previous year questions of jspl through which i could prepare myself for the test.

1932


Zone of protection and tripping scheme of arc protection relay.

1929


why i can not use thimble on capacitor duty contactor

1400