Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the use of Exciter in generator? & what will be the
current of Exciter in 500 KVA DG Set?

Answer Posted / kj

The above answer is true for DG set also. But sometimes on
small DG the output voltage is used instead of the Pilot
Exciter.

the current will vary with load and also the manufacturer
of the DG.

Often now 1-4 amps but some are 20 to 30 amps.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

working principles of cf lamp,incandescentlamp and f lamp?

2311


What is the current carrying capacity of 0SWG,3SWG,10 & 12 SWG solid bare overhead copper conductors?

3502


What is vaccum currcuit breaker.define with cause and where be use it device?

1163


I had applied for JE in PSEB, Can you pls send me the Question bank for related to my field

1915


What is meant by harmonic distortion?

1174


why do we use spark detector inside the slip ring brush compartment 0ona slip ring induction motor?

2153


All the socket in a room become very hot, the Wall was also became very hot and the earth conductor also became live, what in your view might be the possible causes?

1705


what is meant by IGBT how they differ from tyristor ?

2496


if the load is 80 amp for main fuse and 100 amp for breaker so how can we calculate the cable size (cooper ) .

2118


DG Earth Value?

2369


We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.

1924


Please send 110 kv sb station full single line drawing(sld)

2523


What Should be the value of Vector Surge angle at Tripping and how to calculate it?

2102


Dear sir, I have completed DECE in the year 1995. I have work experience in HT and LT LINE more than five years. Now i am doing BE in EEE from rajasthan university. After completion of BE,can i apply "C" Licence sir? Please reply.

1954


hr round

2196