why the the electrical
machine coil are damage ?
How to prevent it?
Answer Posted / santhosh (sggi)
Insulation failure of machine coil due to over load,
It can be prevented by using better cooling arrangements
and overloads.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
What is mean by hot and cold loop testing? What is the difference between them?
sir, I am from EEE branch.On feb 17 iam going to write an Exam for hindustan petrolium corporation Ltd.So plz send me the written exam pattern/Q's/interview questions.please mail to eee_dharmendra@yahoo.com
How LT megger works ?
how does the terminal voltage of transmission lines increase when a capacitor is connected???? This happens not only in transmission lines but also in all circuits. How??? When a capacitor is connected in a transmission line, capacitor also takes energy from the same supply. But how is it able to increase the terminal voltage??? Practically What sequence of events happen during increase in voltage???
in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?
How to identify the start and end of 3phase 12 lead motor if U1, U2, etc numberings are lost or erased.
How will you justify IR value and Charging voltage of any motor,transformer and Cables.......???? . . . . . . . . Plz tell me any body Baljeet Singh, engineer_89@refiff.com
How Self works in DG set
How stabilizer works??
What are the Return ( Monthly / quarterly/ Annual submitted to Electical Inspector for an establishment (Factory in Maharashtra-- Small scale category having seperate HT line of 22KV ) as per Maharashtra Electricity Act
how many single tension hardware are required on a double circuit transmission tower?
1. Why is the speed of shunt motor practically constant? 2. Why dc series motor use to start with heavy loads? 3. advantages & disadvantages of separately excited generator over self excited generator?
we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.
can anybody send me syllabus of rrb section engg (electrical). and also send previous question pepar...
What are the electrical engineer roles and responsibilities in chemical plant?