Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

If single phase voltage level is 230V than why three phase
voltage level is not 660V ?, but it is only 440V.

Answer Posted / m.ubaidullah khan

In three phase power line, each phase is 120 degree from the other phase.therefore, when we draw a graph of phases then two phases have positive values then at the same time the third one has negative value so we can calculate and use only two phases at a time.all three phases changes their position every time so the two phase may be phases 1 &2/phases 1&3 or phases 2&3 gives the values and at the same times phase 3 or 2 or 1 will be at negative interval respectively so cannot be calculated or contribute the value. that's the reason we use 440v instead of 660v.

Is This Answer Correct ?    34 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I want to make street light with solar system ... What may I do for procedure and how much of estimation for each material ... If any one knows guide me and inform this id : aravindd7@gmail.com

1764


Why increase in current leads to increase in conductor temperature?

1072


For RCD (Residual current device) Icu is defined. How i can find Ics for them?

2005


differnce between single acting and double acting solenoid valves

1783


Anybody tell me about modbus hex address of l&t trivector meter er300p??I want to read voltage,current,kwh etc via rs485...If anybody have a manual then send on my mail..Brijeshmodi18@gmail.Com

1849


why incomer bay is required before transformer bay if there are more than 1 nos. of transformer bay.

3023


During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP

1828


a battery is having capacity 100AH and 25% charging .if a load taking 10A & connected 6 hour .what is the final condition of the battery.

1559


How to use earthing on shipments.

1387


Dear sir, I completed DECE In the year 1995.Now i am working in a private company from last 10 years as an Electrical supervisor.The company having a 1000 KVA transformer.Now i try to apply "C" Licence. I am eligible or not.If not eligible,pls give solution.

1707


what id a dry type transformers and its function ?

1712


How we calculate DC inducation moter Amp? Sir pls give me formula......

1786


Draw transformer phasor diagram.(full load,no load)

4106


What is power factor why we should maintain the power factor unless what will happen

1825


why different series of vfds (like allenbradley)are used in industry ?

2240