Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In electrical cables what is U and U0 refers?

Answer Posted / kannan

Rated voltage is a reference voltage used for cable design
and electrical property test, and identified with Uo/U and
Um in the standard. The meaning of the symbols is defined as
per JB/T 8996.
Uo&#19968;Virtual value of the rated voltage between conductor
used for cable design and metallic shield or metallic
sheath, kV;
U&#19968;Virtual value of the rated voltage between conductors
used for cable design, kV;
Um&#19968;Virtual value of the highest working voltage for
equipment, kV.
In the standard: Uo/U=64/110
Um=126

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

please tell me, how i clear the objective test? when i studied form the one book after i solved the objective ,that time i solved that qes. but if i tried solve objective form the other book then i could not solved these que.

1725


what is the saturation point of crgo lamination.

2299


What is the permissable nutral current of three phase system as per IS standards?

2169


How many points does a Circuit can have?

2030


Is there a standard depth of gravel fill in Substation Switchyard? Please give a design/drawing. Thank you.

5460


Write the force balance equation of ideal dashpot element.

1387


What is an alternator impedance value?

2905


What is notching in dc machine?

2058


standard earthing rating for power line..

2172


magnetizer priciple

2155


Why 11kv to be generated in generation station

1726


can we use ZNyn11 transformer instead of Dyn11 transformer in distribution for effectively eliminating harmonics from the industrial loads.

5077


what's producer of XLPE cable laying in undergroung

2189


how does a shunt reactor maintains the bus voltage???

2126


What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?

2047