two bolbs of 100w and 40w respectively connected in series
across a 230v supply.which bolb will glow bright and why?

Answer Posted / sunita

in series current is same.but voltage divides resistance of 4ow bulb is more.it will not glow much brighter as 100 w bulb

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why various test are performed on electrical panels & power cables before commissioning on site & what are these test???

1524


What is the theoretical reason for the size of a zig zag grounding transformer to be 1.732 times less than that of a wye-delta grounding transformer used for the same application?

1822


Does the direction of rotation of d.c. Shunt motor would get reversed if the armature current and field current both are reversed?

650


how solar power plant energy meter multiplication factor

1592


CT Ratio of a energy meter connection is Red Phase : 100/5A, yello Phase : 50/5A & Blue phase : 100/5 A what is the overall Multiplication factor

1200






i want bhel placement paper for electrical if anybody having pl send to my id kavitha867@myway.com immediately

1552


Give the topology of current amplifier with current shunt feedback?

710


How to determine stage of Automatic Power factor controlling Relay(Apfcr)?

1693


Write down the name of 2 lady Bir Pratin of Bangladesh

1465


1.4 What is meant by CT knee point voltage and how would you determine it

1159


What are the different circuits in thermal power plant?

711


What are the reasons for the parallel operation of transformers?

619


Whether should be the oil level in OCTC transfomer? It should be upto winding immersed completely or should be upto tap changer s/w? How it will affect the performance of the transformer. Rating may be 33KVA

1403


why the India electrical supply transmission loss is high when compare to us

1555


We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible

1497