Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why the transformers are rated in KVA. ? in new view.

Answer Posted / pradyumna171


Power given to the transformer is Apparent power (K)
it is the supply power of the power house and the power
given by the transformer to the Load is the true power or
Active power which is actual used by the load and rest is
the reactive power i.e. square of apparent power including
iron loss & copper loss in KVA = square of true power in KW
+ square of reactive power in KVAR. A sound transformer
efficiency is 98% (input power- Iron loss (k) & copper loss
= output power).
For full resistive load (at unity pf ) a 100 KVA
transformer gives 100 KW (approx.) true power, and for
inductive power at .8 pf the same will able to give 80 KW
(approx.) true power, but the types of load (its pf) is not
know before which to be connected across the transformer,
this is only why the transformers are rated in KVA and it
is meaningless to discuss about the iron loss and copper
loss because the Inventor and UPS are also rated in
KVA.

In other hand or in simply we can
say due to unknowing power factor the transformer,
generator etc are rated in KVA. In heavy size transformer
copper loss is more and it vary with load and Climate i.e.
transformer oil condition but it is not main reason for
rating the transformer in KVA.


Pradyumna Chandra Panda
Berhampur Mob 9861357949

Is This Answer Correct ?    10 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to reduce the static electricity producing in solvent room? By P.D.Patil BioCon

2025


how does the thyistor work in dc drive?

1925


when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you

1742


difference between ac series and parallel circuit

1974


After synchronization with grid what is the demand value QKVAR and how we will maintain that?

2211


How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.

1991


What is the general power factor & min. power rating of TV,LCD type TV, CRt type TV, Scanner, printer?

1991


what is earth resistance? how to measured? and give values at power station and mcc area?

1917


How can eliminate noise problem inside temperature controller temp. variation due to contactor chattering problem.

1567


Why it need to form a capcitor when it not been in use from three or two year. Plz describe it technically.

1884


I am inpecting a 10kVA UPS what tests should i do and should i observe?

2164


Why we use mho Relay in long transmission line?

1388


Which type of DG need Netral Earthing?

5207


Draw the line diagram of diffretial relay connected to transformer?

2375


is it value of power factor is more than unit. whats effects in the source supply

2033