Answer Posted / jerry
THOMAS SEEBECK discovered that if two wires made of dissimilar metals are connected at both ends to make two junctions,when one is heated,a small amount of current would flow through the circuit .when both ends of the wires are twisted together and one end is heated,the two wires produce an open circuit voltage that is called seebeck voltage.The open circuit voltage is proportional to the amount of heat added to the junction.this principal is used to detect temperature in the Thermocouple.
| Is This Answer Correct ? | 10 Yes | 0 No |
Post New Answer View All Answers
What types of Instrumentation Related Questions can an Interviewer ask in a Telephonic Interview ?
give me the formula for analog to digital converter and also d to a converter
i am from instrument branch i want paper patern of mahagenco . any pevious years paper regarding my branch send me please . please.....
why I need valve guard and whats different between guard and positioner ??
What is the start up procedure of desalter
How to convert milliampares into flow??
how to measure oxygen which methods are using?
what is the difference between magnetic flow meter and mass flowmeter
Is it ok, to use non-contact type Radar type LT, on a tank that is half circular from the bottom side? If yes the, isn't the waves gonna bent in other directions?
What is the constant voltage unit?
hello friends, can you please send me the model paper or question paper to be prepared for hpcl examinations????????? You can mail me at rahim_here@yahoo.com waiting for your reply........... help me .. plz.....
Give an example where you had aproblem on the job, and tell me how you solved the problem. and the finalvoutcome.
What is intrinsically safe system?
how pressurize drum calibrated ?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =