Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why transformer ratings in kva?

Answer Posted / pradyumna chandra panda

Power given to the transformer is Apparent power (K)
it is the supply power of the power house and the power
given by the transformer to the Load is the true power or
Active power which is actual used by the load and rest is
the reactive power i.e. square of apparent power including
iron loss & copper loss in KVA = square of true power in KW
+ square of reactive power in KVAR. A sound transformer
efficiency is 98% (input power- Iron loss (k) & copper loss
= output power).
For full resistive load (at unity pf ) a 100 KVA transformer
gives 100 KW (approx.) true power, and for inductive power
at .8 pf the same will able to give 80 KW (approx.) true
power, but the types of load (its pf) is not know before
which to be connected across the transformer, this is only
why the transformers are rated in KVA and it is meaningless
to discuss about the iron loss and copper loss because the
Inventor and UPS are also rated in KVA.


In other hand or in simply we can say due to unknowing power
factor the transformer, generator etc are rated in KVA. In
heavy size transformer copper loss is more and it vary with
load and Clemet i.e. transformer oil condition but it is not
main reason to rating the transformer in KVA.


Pradyumna Chandra Panda
Berhampur Mob 9861357949

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the distance between each insulator in 33kv transformer and how can it calculate

2127


For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?

1893


How to calculate that clean water supply in one Day from 150 KLD STP?

1943


what may the reason for vector shift in a generator?

1827


Why synchorised generators are used for the production of electricity?

1133


How much inductance or resistance require as a starter in series with induction motor of specific capacity(e.g. 5 hp) ? What is formula for it ?

1910


Why the efficiency of generator is more than motor in swinburne's test

1970


what maximum range of star & delta in hp or kw ?

1642


What is the formula to calculate distribution transformer De-rating on iron losses basis

1790


Name two types of electrical analogous for mechanical system.

1153


i want to run 11kv star connected motor in 6.6kv with delta connected throught inverter, is it possible?

1979


what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??

9393


What are the two types of compensation?

1046


Why mostly the HV side of transformer has Delta?

3160


Where burned of electricity,when,who, & why.

1930