Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why transformer ratings in kva?

Answer Posted / pradyumna chandra panda

Power given to the transformer is Apparent power (K)
it is the supply power of the power house and the power
given by the transformer to the Load is the true power or
Active power which is actual used by the load and rest is
the reactive power i.e. square of apparent power including
iron loss & copper loss in KVA = square of true power in KW
+ square of reactive power in KVAR. A sound transformer
efficiency is 98% (input power- Iron loss (k) & copper loss
= output power).
For full resistive load (at unity pf ) a 100 KVA transformer
gives 100 KW (approx.) true power, and for inductive power
at .8 pf the same will able to give 80 KW (approx.) true
power, but the types of load (its pf) is not know before
which to be connected across the transformer, this is only
why the transformers are rated in KVA and it is meaningless
to discuss about the iron loss and copper loss because the
Inventor and UPS are also rated in KVA.


In other hand or in simply we can say due to unknowing power
factor the transformer, generator etc are rated in KVA. In
heavy size transformer copper loss is more and it vary with
load and Clemet i.e. transformer oil condition but it is not
main reason to rating the transformer in KVA.


Pradyumna Chandra Panda
Berhampur Mob 9861357949

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

is there any chart showing the suitable cable size according to AMP and length ? for three phase motors

1386


What is electrical cable termination

2611


What type interview questions ask in Electrical technicians

1765


Greeting to all members, How to calculate spill current when we have different ratio CT and Class for REF(Low Imp) I have 500/1A 5P20 @line side n 400/1A CL.X @ Neutral.

2981


If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..

2477


Why syn. Generators are used for the production of electricity?

1138


what are the Alarm, Trip & Safety equipment (Issues) present in Power Transformers pls Mail it to ashokbabunhce@gmail.com

1896


1) why a dg set shows variation of power factor and load when synchronised with other dgs? 2)Why the load sharing is not become equal in all dgs?. 3)When a dg set will not run on auto start?

1986


what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.

2322


why zero sequence impedance measurement is not applicable for single phase GT

2183


What kinds of decision are made about CT from it's Knee point(voltage & current)?

5049


What the difference between three phase contactor (coil 110vac) & three phase SSR (control voltage 110Vac)? May I use contactor in place of SSR?

2150


If rotor works in clock wise what happens

1898


what is cause of static electricity? I experience shock when i touch metal equipment in a room ,furher check shows earth leakage showing 80ma at the DB near to the 400 MCCB?

1881


why in a swquence network representation, the negetive sequence generated voltage is taken as zero?

1992