Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the function and use of oil filled cables specify
its advantages and disadvantages

Answer Posted / gargee

In case of oil filled cables, the channels or ducts are provided within or adjacent to the cores, through which oil under pressure is circulated.

1.1 Advantages
The various advantages of oil filled cables are,
1. The thickness of insulation required is less hence smaller in size and weight.
2. The thermal resistance is less hence current carrying capacity is more.
3. The possibility of voids is completely eliminated.
4. The allowable temperature range is more than solid type cables.
5. Reduced possibility of earth fault. This is because in case of any defect in lead sheath, oil leakage starts, which can be noticed before earth fault occurs.
6. Perfect impregnation is possible.
1.2 Disadvantages
The disadvantages of oil filled cables are,
1. The initial cost is very high.
2. The long length are not possible.
3. The oil leakage is serious problem hence automatic signalling equipment is necessary.
4. The laying of cable is difficult and must be done very carefully.
5. Maintenance of the cables is also complicated.

Is This Answer Correct ?    11 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why armature rheostat is kept in maximum position?

1100


how to check regenerative load in drived motor

2227


howmany electrician should maintain for a 1000 kva used plant... in kerala..

2100


We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.

1867


i need the details about bhel exam.how to apply for that.please send to my email-id.thenmozhi2k7@gmail.com

2008


what is earth pit , how we can measured it, what earth rods reference

2606


what questions will be asked for 11/33KV licence interview APSEB hyderabad. Can any one share question and answers.

18441


IN 1000kva transformer where the oil and winding temperature sensors is connected

2524


please explain how to do 'pole drop test' on generator?

2900


when qty of cable being purchased is not sufficient according to the standard,what should the inspector do to ensure its quality according to the standard?

2074


Is it possible to download the Siemens Selection Chart(TYPE 2 coordination) for 1) fuseless selection 2)Fuse selection

8219


What is d main advantage of using double circuit 3 phase transmission ?

1934


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING) I O (current operating)?

2202


In ups static switch if i gives the supply at output end it will open the circuit in stactic switch or not if it will open then how it operates.

2304


how to calculate distance between busbar supporters for LT panel, what are the factors influencing in this design

5312