Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the application of over current relay?

Answer Posted / nikitha

Used in transmission lines;
near alternators and substations- non directional
else - directional

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]

2390


When calculation of fault current and fault Kva is to be done,why always we use per unit value and why we consider the base kva?

1912


what is the difference between 4pole & 6pole DC Motors & give advantage ?

1911


hello if any one have papers vof hpcl or sail, plz send me

1928


what is the calculation involved to design the heater to heat 10KL of water in temperature control unit?

1939


what topics we have to concentrate for power grid et.written test.and tell what to read for english synonyms and antonyms.

1957


How delta connection in the primary of distribution transformer reduces harmonics?how delta connections reduces harmonics?Please answer me...Hope that question is correct.

2225


what is the difference between vector scale and vector diagram?

4472


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1815


please give me all the Alarm .Trip ,Safety Relays & Conditions of Chiller mail me on ashokbabunhce@gmail.com

1835


There is air in a room . the top and bottom of the room are at constant temp. T1 and T2. DRAW THE temp profiles if a. T1 greater than T2 b. T1 less than T2

1897


What is the difference b/w fanuc alpha series 16i and 18i controller. what is stand for i

2079


What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

2011


how to select automotive wire by mathematical equation with given current, vlotage and resistance

2364


what's the requirement of Dy11d0 connection of 3 phase transformer?what's use of it?

7996