Answer Posted / pankaj kumar
VT and CVT are besically use the same fundamental physics for measure the voltage at sedondary as according to its primery..but the besic diff. Is VT usually use for measurement to voltage for protection ckts as well for metering purpose, CVT also can be use for the same purpose but additional advantage with CVT is it can be use in communication purpose as it does have the capacitors as a fliter who can diff. The communication signals and protection signals or you can say tele protection also the purpose depands on the classes of VT and CVT as according to requirement of protection and communication like over voltage pro. Distance pro. Or metering as per requirement
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
What will happened if the neutral of secondary of Xformer ( Star point) Note it's above KVA rated Xformer
what is the size of cable for 15kw motor and 85 meter cable length using with vfd
1600kva capacity Transformers how the bucholz relay,Oil temperature,winding,surge relay relays setting are to be done
Usually in the L & T make MCC feeders' power circuit,we have BMR after the MAIN CONTACTOR.,can we interchange their position, keeping the control logic same???
sail kaott diploma ece ke interviw me qus.kis parkar ke aate hai aur G.S me kya puchate hai kya sameedyaan me kis parkar ke qu.puchate hai
a battery is having capacity 100AH and 25% charging .if a load taking 10A & connected 6 hour .what is the final condition of the battery.
What are the electrical engineer roles and responsibilities in chemical plant?
can we use trip light with bus coupler?
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
why transformer ratings in kva? & DG ratings in kva? & Motor ratings in kw/HP?
how we design a pannel to start 10HP motor with the help of star delta starter?
please send me jindal previous aptitude and technical question and answer.my email id is deep_raj@live.com
What do you mean by phasors?
Define early construction of human being
rajha power sector details