How to find out turn down ratio of Pressure transmitter?
Answer Posted / vinoth.s
Turndown RATIO= MAXIMUM ALLOWABLE VALUE/ MINIMUM CONTROLABLE
VALUE.... SIMPLY DIVIDING THE UPPER RANGE/ LWER RANGE
| Is This Answer Correct ? | 5 Yes | 3 No |
Post New Answer View All Answers
in differential pressure transmitter,min&max pressure range for hp&lp
Instrumentation symbols interpration, P& ID, Logic diagram analysis, Electrical drawing analysis.
steps for installing orifice plate?
How flow can be measured with dp?
How does your previous experience relate to the job you are applying for ?
How to Calibrate Radar Level Transmitter in Field
what is the importance of CV in the control valves? how it is calculated?
Somebody tell me in what way i need to prepare for csio pgrpe(adv instrum eng)interview?what all the quest can i expect?
I installed the smartplant instrument v8, but can not be opened, that always said: "INTools 2007 hardlock no found". So Could you help me how to do for that?
How an rtd work, and what volts/current goes to a rtd to measure the resistance?
how do calibrate the valves.. with clear manual
What do you know about gail?
what is isloted barrier how it works and what are the main purpose.how it make safe area.
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.