Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Dear sir,We have a 7.5hp motor,it was running smoothly and
suddenly one winding is carring more current then
others(r=6.5,y=6.3,b=10)..whts wrong with tis...?

Answer Posted / kingniki

We can check by continunity on winding from multimeter and that time it shows that motor becomes unbalanced

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is inter connected dc generator?

2885


I am interested to know what does 15 KVA DG set actually means? If I dont know the DG rating, is it possible to identify KW by simply knowing the diesel consumption?

2235


Explain the function and difference of Restricted earth fault, simple earth fault and sensitive earth fault with connection diagram.

2709


can anyone explain 11kV 3core cable megger,hi pot test procedure with connection details?

3327


According to IEC60034-14, When the vibration monitoring system required for motor Bearing. above which KW, it is required? and for what type of bearing the vibration probe is provided.

4222


How to calculate KVA/VA rating of PT or CT from primary & secondary voltage or primary & secondary current?

2499


What is the effect of solar radiation on the design of an Isolated Phase Busduct?

2414


Difference between RCCB, RCBO and ELMCB.

4139


A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE

2632


What is the function of RCBO? What are the different sensitivity ratings & each application?

2871


what are inductive and capacitive voltage transformers.what are their applications

2004


Does the direction of rotation of d.c. Shunt motor would get reversed if the armature current and field current both are reversed?

1204


WHAT IS THE PARTIAL DISCHARGE TEST?

2172


why impedance relay is used for medium transmission line protection

2366


What is notching in dc machine?

2054