Answer Posted / pps
NGR means neutral ground reactor. Normally it is used in
Generation stations and long line shunt reactors. Main
purpose is to limit fault current when earth faults. and
also it acts as a phase winding when one of the reactor
winding or generetor winding or phese in lines open or
grounded.
| Is This Answer Correct ? | 12 Yes | 5 No |
Post New Answer View All Answers
given data are load current & power factor cable core size? plz any one update the calculation formula
What is the formula for selecting the cabels according to load? How to calculate what sq.mm cabel to be used?
I am abt to give IOCL intrv.Plz sir guide me for IOCL intrvw (Electrical).Which subject to be consider. questions are generally asked from which subject.Plz help me out.
why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.
What is ST and specify its range of voltage.
difference between power surge and switching transient
In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.
The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.
Meter p.t. ratio= 3×230/400 , c.t.ratio = 3×1 (2) A what is m.f.
What are unstable systems?
why is using sensor?what is differece between photoelectric and proxmitty?
In synchronization circuit what is the function of Interposing voltage transformer(IVT)and Reverse voltage transformer(RVT)
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
How much inductance or resistance require as a starter in series with induction motor of specific capacity(e.g. 5 hp) ? What is formula for it ?
What are factors to be considered while we selecting the Core Balance Current Transformer for Earth fault protection