why select the 3 phase power supply system in electrical system.
Answer Posted / nilamani umashankar jena
IN 3 PHASE POWER SYSTEEM THE VOLTAGE REMAINS CONSTANT AND
WE GET QUALITY POWER
| Is This Answer Correct ? | 3 Yes | 1 No |
Post New Answer View All Answers
Why we use circular(Stepped) cross section in transformer core?
if 2 coil of 1000W connect in series and 200 v is applied across it . then what is the total power of coil when coil have only resistive load .
Please send 110 kv sb station full single line drawing(sld)
Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV
Approach of a cooling tower is the difference between temperatures of what factors?
what is the function of choke in the flourcent tube lights and why the colour is in white mostly in flourcent tube lights
Please tell me the earthing procedures adopted for the STAR-STAR 3 Phase transformer in india and give a better sugession for earthing
How eddy current generation support the idea of train braking?
what is resver in electrical enginnering with answer
what is is the potential diffrence between two phase ?
For a 6.6kV Motor it is recommended to do megger test with 500 V d.c and not more than 5kV d.c but the Hi voltage withstand test should be performed by 12kV AC. Why the dc voltage test should be limited but AC voltage withstand test could be with such a high voltage?
diameter of cable and core is doubled then the value of capacitance is
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
what is the maximim current drawn by 1 phase and three phase welding machine