A 11000/415V distribution transformer is fed 415V upon it's LT
side,Do I get 11000V upon it's Primary side ?
Answer Posted / uselescrapytwit
Yes because the losses are allowed for via the % in the regulations. ALSo the transformer may be a multi tap to allow adjustment of secondary out put.
All in all its close enough to satisfy the regulation primary secondary either way round.
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
write a c++ code that receives an integer number and display the sum of the number and its revers integer?
what is the difference between online & offline caliberation of KWH meters. Can Digital meters be caliberated
what is plunger and what's the use of it in motor alignment?
i am electrical and elctronics engg passed out in 2009 want to attend for reliance placements.plz send me apttitude ,technical and hr question answers to my mail plz. my mail id-kat.bindas@gmail.com
In EB metering we face problem kva jump even in no load condition.can any one help to control this
What type of pipe material G.I or M.S is used for sprinkler system?
Does the motor power displayed on the Motor name plate is the mechnical power motor delivers or it is consumed power from the system?
Dear Mr B C pal...Can you plz. put some light on principle of operation of Z-Ct in conjunction to its use with 1Cx1000Sqmm HT Cables & Directional Ground Fault / Over Voltage Relays...Regd..Parag v K 9899115632
What is phase cross over frequency?
How much weight an electrical engine can pull??
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
Is a direct shorth ciruit on a branch MCCB in a Low Voltage Switchboard a correct means of tesing the performance for discrimination?
Why is it prefer to initiate circuit breaker failure by "86" lockout relay not by "94" tripping relay ?!
WE HAVE THE DC RECTIFIER 1500A, INPUT VOLTAGE IS 3 PHASE. HOW TO CALICULATE THE LOAD? 3 PHASE SIDE EITHER dC SIDE. PLEASE SUGGEST ME
what are the different methods for the starting of a synchronous motor.