Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is difference between 5A and 100A CT constructional wise
and operation?

Answer Posted / sudhakar.g

Depending upon its class and calibaration we use the CT's
of 5A and 100A....Genrally if we use on LTside we can use
5A and its class...for 100A it genrally prefer on HT side
like HT panels, Metering cubicles......why we are using CT
because how much Current we are consuming and it placed on
Outgoing cable of Incoming breaker....CT's outgoing we can
use the control wiing like LOAD manager, Relays because
those equipments want low voltages...
If u have any queries pls contact me
sudhakar28485@gmail.com or 7760362623

Is This Answer Correct ?    3 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is big transformer parts and their function ? Ty

2138


Its possible to use 3core 2R of 240 sq.mm cable for 3phases & separely 50sq.mm 3core cable fully for Neutral for connection of PCC to MCC 3ph..4wire system?

2054


What the formula for calculating no.of earthings & size of earth strip for 100mX90m shop.

2302


How many types of colling system it trformers?

1133


what are inductive and capacitive voltage transformers.what are their applications

1900


hi, could someone help me to find a control design for syncronising panel .

1653


Why a Permanent Magnet Generator has higher frequency as compared to frequency of main alternator?

1918


why we change the direction of winding in rotor ?how we make the north and south pole?

1987


What is the one main difference between ups & inverter ? And electrical engineering & electronics engineering ?

1090


A 3 phase transformer's (Y-Y) Y and B phase is (Y and B connection not broken) broken from neutral and R and Nutral connection is ok, what will be the relay tripping and why

1902


How can claculate to attain the desired PF in the line ( HOW Much KVAR is required ) Pls Give the formula? Equate Petrochemical 0 1 how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec. 0 1 What will happened. if we feed 3phase supplay to the stater with out insert the rotor. How much current will flow through the stater winnding? Equate Petrochemical 0 1 What is required of exietation to the alternater. 0 1 why star point of HT motor not earthed? Equate Petrochemical 0 1 Why we are getting low voltage in star connection? Equate Petrochemical 0 2 What's ND relay & it's functions? Equate Petrochemical 0 2 How instantanious short circuit current is calculated? its formula? Equate Petrochemical 0 2 What is servo Motor? What's the advantages of this motor over Induction motor? Equate Petrochemical 0 2 What is core CT & it's function? Equate Petrochemical 0 3 what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY L & T 0 4 What is required of exietation to the alternater. KNB 1 23 what is the design voltage for 6.6KV 2000 KVAR HT capacitor? Consultancy 0 3 Pls explain about vfd control?Where it is used, Give some example? siemens 1 22 Please explain me abt PQ diagaram in the power sector. 0 9

2099


While performing stability test of differintial cts how to know the voltage and current on both side of the transformer?

3496


why we use two slope(differential & restraining) in differential relay.but in busbar protection differential we are using only one slope?please explain

2194


at meter room 50 hrc switch installed,but there are not get earthing proper,so what happen?and 11kv transformer out put going in to hrc main 400a three nog each? so earthing is require for all switch? (some customer made earthing at there home.)

1852


ht side line to earth voltage

1524