is electrons really flow or they just vibrate at their position?
Answer Posted / devsingh boda
I think in semi conductors electrons(Ex: In p-n junction diode some electrons cross the depletion layer) flows really whereas in pure conductors they only oscillate and just energy is transferred from one electron to the other.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is the comparison between 30mA DP RCCB and 100mA DP RCCB and can replace it against 63A MCB
how to setting Load amps tripping time and extra settings for load Transformer protection relay with RMU panel using C&S model relay..?
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.
How can you calculate the size of the down conductor cable for the lightning protection system. Is 70mm2 cable can replace 95mm 2 bare copper cable when the copper tape size is 25Wx3 thk mm.
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
what is the electrical?
kindly send me 11KV MV motor differential protection procedure by primary injection method.
does any one know where we can purchase insulation oil for high voltage oil filled cables
salam&hi, i need to know about how can i calculate an enough current for the new building before i submit it to the suppliers
what is capacitor voltage transformer?? how it is different from potential transformer?
What information we need to prepare relay coordination chart
Can anyone explain me about the capacitor calculation
how are reversing the direction of dc motor
how generator load test is conducted?what are the steps?