Difference between induction motor and synchronous motor?
i Think Synchronous motors operate at synchronous speed
(RPM=120f/p) while induction motors operate at less than
synchronous speed (RPM=120f/p – slip). Slip is nearly zero
at zero load torque and increases as load torque increases
am a right pls guide & send Other Comments
Answer Posted / arun
THERE R MANY DIFFERENCE IN SYNCHRONOUS AND INDUCTION M/C
1)IND M/C IS SELF STARTING E.G.3 PH INDUTION MOTOR
BUT SYNCHRONOUS M/C NOT.
2)SYNCHRONOUS M/C RUNS ON SYNCHRONOUS SPEED WHILE IND. M/C LESS THAN SYN SPEED.
3)SYNCHRONOUS M/C CAN WORK ON LEADING AND LAGGING BOTH BUT INDUTION M/C ALWASY RUNS ON LAGGING PF.
4)EFFICINCY AND COST BOTH OF SYNCHRONOUS M/C IS MORE THAN INDUCTION M/C OF SAME RATING.
5)INDUCTION M/C IS SINGLY EXCITED BUT SYCHRONOUS M/C (ONLY MOTOR NOT GENERATOR) IS DOUBLY EXCITED .
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
how to calculate transformer turn primary & secondary side 11kv to 420v
Pl. give me checklist for installation & commissioning of machine tool.
what is the difference between RMS & TRUE RMS VOLTAGE
can anyone send me some sample question regarding power grid corp
please send me previose rrb junior engineer qustion papers
What is vaccum currcuit breaker.define with cause and where be use it device?
How I calculate the ELCB for circuit breakers?
Briefing the effects of ASR and ACR of a double closed-loop speed regulating system.
i ha done my 10th with 71% ,ITI with 81% 11th with 75% 12th 43% apprentiship with 71% in SAT i secure 1390 ,TOEFL 27 i was refused four times and in all me interview visa officar told that i am not Qualify for study in USA but i completed my 12th yes i got low persentage in my 12th but i seen to much student they already got visa with them 3 or 4 backlocs so why they are refused me ?
I AM GOING TO ATTEND APTRANSCO ON 26TH OCT 08.PLEASE SEND ME ANY MATERIAL OR TYPE OF QUESTIONS OR EXP QUESTIONS.
How to calculate impedance volt in Transformer?
I WANT TO know WHICH WAY IS BETTER FOR CONNECTION BETWEEN POWER TRANSFORMER AND MAIN DISTRIBUTION PANEL. 1-IS BETTER WE USE CABLE? 2-IS BETTER WE USE BUS DUCT? my transformer rate power is 2500KVA
How we select the vector group of 3phase power transformer?
to hook up ten 50 amp rv pedastels at a lenth of 600 feet from the service what size will my service need to be and the size of wire will I have to run to each pedastel in series??????
Dear all: Recently we got a question about Interface between PMS and SAP-PM.once we got a update message from PMS.we should set the deletional flag for functional location in SAP system.Is there any FM or BAPI to use?There are only functional location create and change provided by SAP. Best regards!