can you give main difference between ELCB And RCCB?
Answer Posted / stephen nadar , p.k.kudiyirupp
elcb means earth leakage circuit breaker which operates when
there is a leakage of current from phase to earth.
Rccb means residual current circuit breaker which operates
when there is a difference in current between any two
phases.This differential current is called resdual current.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How to determine the breaking capacity such as break down current and break down voltage for VCB and CT's.
There is any especial requirement for motor to drive through with VFD?
How many Zones can be in Conventional type fire alarm system & how can we detect the fire in Conv. type FAS?
If the feeder rating is 7.5 kw or 10 HP star-delta feeder, MCCB is taken as 63 a, contactors-32 a, how much will be the OLR rating or which range OLR should be considered when we concern about type-2 coordination?
how current is reverse from its normal direction during the fault?
USE OF 8 WAY PAN ASSEMBLY
what is the advantages og idmt relay over magnetic relay??
From reading, Under voltage relay used also as phase sequence relay now, Why I use under voltage and phase sequence relay in the same circuit (ATS)?
what is effect of 5amp fuse on 2mva pry protection of transformer
Draw the wave shape of armature current in a generator subjected to a sudden three phase short- circuit at its terminals. Define various reactance of generator from this wave shape.
explain the functions of main isolation switches
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
why is the power generator connected as star earthed or star earthed through reactance and what its features ?
Hi,I am working in abroad for more than 3 years in a company operating with 11kv and 6.4 MW power. I need c licence in India,can I? some other says only i can get if i work for 2 years in india only! anybody kindly clarify by doubt.Thanks
what are symmetrical and non symmetrical components in electrical installation.