i have one ground earth for my shop but now he showing 11v how
ever my machine engineer said that he require less than 3v how
can we reduce it, i have put 8 bucket salty water in it
Answer Posted / harikesh yadav
Your Earthing not working properly please checked earth
Wire and if broken wire please reconnect again
8V different is not acceptable.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.
what is sustainable current of any conductors . a bare busbar or pvc cable has different sustainable current .
in science exhibition how lamp can blink when you clap near the lamp ? thank you
What are the effects of adding a zero to a system?
How Load Factor, Demand Factor, Diversity Factor etc best applied in designing an electrical circuit? Is it allowed to consider these factors in each and every panel in an electrical distribution system? Can any body suggest a good book for reference?
I am inpecting a 10kVA UPS what tests should i do and should i observe?
What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?
There are Two questions about Steam Turbine Generator... What is HRSG bypass of LP, HP used for in power generation? In particualar, in the event that fault of HP bypass, there would be STG TRIP in operation but none on the LP bypass fault...what's the reason ?
what kind of quetions will ask in BHEL in interview? Plz help me?
WHY THE COLOR OF OUTDOOR TRANSFORMER IS BLUE ONLY???
what is difference between bus coupler and auto transfer switch
How to select a transformer group to connect a 0,433 KV generation with 33 KV grid in bi directional flow of current
which phase is preferred for connecting 1 phase vt used for synchronizing OHL? WHY?
What are the Return ( Monthly / quarterly/ Annual submitted to Electical Inspector for an establishment (Factory in Maharashtra-- Small scale category having seperate HT line of 22KV ) as per Maharashtra Electricity Act
solar inverters was not connected to the nuteral link .this nutwral possible to any other systems