Answer Posted / abhishek kesarwani
The difference of synchronous speed and actual speed of Motor.
See the rotor rotates by the torque generated because of magnetic field, in the induction motor the field is rotating magnetic field which rotates with synchronous speed (Ns=120f/P)hence the rotor rotates on the speed which is lesser than synchronous speed so the difference of synchronous speed and actual speed of Motor is the Slip.
| Is This Answer Correct ? | 3 Yes | 3 No |
Post New Answer View All Answers
why we are not giving the zone 1 trip command to the master trip relay
can someone explain that how the speed of the protection system affects the fault level calculation?
How can claculate to attain the desired PF in the line ( HOW Much KVAR is required ) Pls Give the formula? Equate Petrochemical 0 1 how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec. 0 1 What will happened. if we feed 3phase supplay to the stater with out insert the rotor. How much current will flow through the stater winnding? Equate Petrochemical 0 1 What is required of exietation to the alternater. 0 1 why star point of HT motor not earthed? Equate Petrochemical 0 1 Why we are getting low voltage in star connection? Equate Petrochemical 0 2 What's ND relay & it's functions? Equate Petrochemical 0 2 How instantanious short circuit current is calculated? its formula? Equate Petrochemical 0 2 What is servo Motor? What's the advantages of this motor over Induction motor? Equate Petrochemical 0 2 What is core CT & it's function? Equate Petrochemical 0 3 what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY L & T 0 4 What is required of exietation to the alternater. KNB 1 23 what is the design voltage for 6.6KV 2000 KVAR HT capacitor? Consultancy 0 3 Pls explain about vfd control?Where it is used, Give some example? siemens 1 22 Please explain me abt PQ diagaram in the power sector. 0 9
if voltage bt phase & nutral is 38v in a panel board . whats the root cause.
Why do we perform an open-circuit test and short-circuit test on the transformer?
what is the value of combined earthing in general electrical circiut?
What is inrush current? how can calculateit? what is the affect of it?
What is dc current source?
i have 3500 amp load and select current transformer and perches.how i calculate .please understand
What is a feedback in control system?
in power generator normaly voltagr betwween esth to neutral is 0 but my work place generator show the volatge is 60v any body know why? thanks
cc of scorpio?
can we find the inductance of a induction motor?
WHAT IS THE DIFFERENCE BETWEEN GENERAL INVERTER AND SOLOR INVERTER TELL ME PLZ
DEFINE BREAKING CAPACITY OF BUSBAR & HOW IT IS CALCULATED?