I have 475 hart communicator. this is not support any new
type of instruments such as tranmitter,fieldvue DVC6200.DVC
200 since i got point out need to upgrade . my questions
is how can upgrade new instruments software in my 475 hart
communicator. can any answerplease>?
Answer Posted / kashif
You have to upgrade the HART simply install the upgrading software at laptop or PC (Resource CD is with the HART supplied by Vendor and if you have no CD just download from Emerson website) then remove the system card from HART insert into card reader and download DDs version from software that is installed in you laptop .check your device version from instrument tag plate.Please follow this link to download DDs version software.
http://www2.emersonprocess.com/en-US/brands/Field-Communicator/Pages/EasyUpgrade.aspx
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
what is diffrance between FF & SMART, explain with difination
what about your moleg in pogrees with company
what should he know if he is an assitent engineer instrumentation in cement industries of experience of 10 - 15 year.
How to decrease opening & closing time of on/off valve?
How is flow measured in square root?
please send data bank of quetions answers on analytical instrumentation.
sir,would you please send me the Hindustan petroleum corporation limited papers(HPCL).my e-mail ID is ujjwal_sharma1983@yahoo.com
what is RTV function in in process control?
Draw a wheatstone bridge circuit showing supply, meter and 3 wire RTD connection
installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,
Draw a P& ID showing – orifice flange, plate, dp transmitter, isolation & bypass valves and tubing.
What is surge and how is it prevented, what is the purpose of bypass valve across AS valve.
Describe a time when you anticipated potential problems and developed preventive measures.
how u choose thermowell lenght n pnumatic C/v size?
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....