During Load testing of battery charger with temporary AC Generator .When reach 70% load Generator immediately shutdown .we could not able to Recognize ,what is exactly problem .Please kindly clarify us
Answer Posted / binod
AS WE HAVE TWO PART OF THE PROBLEM.
1ST PART IS GENERATOR &2ND PART IS LOAD TESTING OF ABATTERY
CHARGER.
1ST-1) THE GENRATOR IS DTIVEN BY THE ENGINE.
CAPCITY OF ENGINE TO RUN THE GENARATOR FOR DELIVERING ITS
FULL LOAD TO BE CHECKED BY ANY OTHER MEANS. INTERLOCKS OF
TEMPRATURE VARRIATION OF GENERATOR TO ENGINE BE CHECKED.
2ND- CONNECTIONS TO BE VARRIFIED,BATTERY CHARGER
SEMICONDUCTOR ELEMENTS RATING HEALTHYNESS &CAPACITY TO BE
CHECKED.THE LOAD WHICH IS GIVEN TO TEST IS CHECKED IN
INCREASED TEMPRATURE.THE LOAD MAY BE SHORT CIRCUITED AT 70%
CAPACITY WITH INCREASED TEMPRATURE.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)
Which motor connection is preferable star-delta or delta-star?
in dc shunt motor if field winding is shorted then
How does an oscillator differ from an amplifier?
How a band pass filter is constructed?
what is package substation.how many types they have
How to calculate multiplying factor of dc energy meter
A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?
howmany electrician should maintain for a 1000 kva used plant... in kerala..
While HT line put on to activate ACB in low tention panel VCB tripping instantly.why it happens
How does a battary stores charge in it? please explain in simple manner and in detail.thanks
electrical
hi everybody how to design string combiner box (scb) internal parameters like bus bar and spd (surge protection device and fuse which place to set that,and also bus bar one particular cross sectional how much heat generated and how much power loss tell me Clearly and briefly
explain PV modules in solar energy generation.
how balanced in star delta connection ?