Can the Neutral and Body Earthpits of a transformer
conncted together by Earth strips under ground.

Answer Posted / binod

TR BODY SHOULD BE EARTHED WITH TWO DIFFERENT EARTH PITS
SEPARATLY & NOT CONNECTED WITH NEUTRAL EARTH PIT.YNO/YNO
POWER TRANSFORMERS THE PRIMARY EARTH IS GROUNDED SOLIDLY &
SECONDARY EARTHS CONNECTED THROUGH NGR/NGT AS PER THE
REQUIRED LOAD PHILOSHOPY.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

please give some hindalco placement papers for written exam

1344


ow can i get certificate of competency as electrical supervisor and my diploma in electrical engineering from jalgaon.

1865


Can clean earth cable be considered as low current cable

1548


1)What is a Triode? What are its uses? 2) What is a Triac? 3) What is a Thyristor?

2065


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1340






In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

356


c++ write a program to use a fuction call "max"which accepts an intger arrey of size5.as an arrument and return the larger and smallest of the arrey to main without changing. the original changing of the original position of the element of the arrey.

1470


I want to know Electrical Circuit?

1709


WHAT IS MEANT BY OVER EXCITATION IN GENERATOR TRANSFORMERS? DESCRIBE IT.

2172


How impulse levels are calculated that for 11kV impulse is 75kvp, for 24kV impulse is 125kvp ?

1546


Use of switch mode power converter in real-time basis?

625


71ohm,111ohm,95ohm,179ohm in calculate the total ohm in series circuit

1235


How can we calculate cable size in Low voltage & high voltage

1155


What is UPS and How do you maintain the UPS Maintenance? Brief Description on UPS maintenance.

2125


i installed 100kva ups. what KVA genset they should provid in input side? plz any update formula or ans with reason.

1863