Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In transmission line the line power loss only accured at
resistance the inductance and capacitance wont consume power
is it correct?

Answer Posted / sandeepraj

the transmission line pocesses only resistance that means it is not like that it dose not have inductance and capacitance, transmission lines have very little percentage of L and C which are due to nature of meterial(transmission line). so the losses occur are obviously due to resistance.
where as during distribution due to inductance of loads some power is stored which reduces power factor and this power factor is bought back by adding capacitor banks.
in india the transmission losses are 5 percentage

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How many Zones can be in Conventional type fire alarm system & how can we detect the fire in Conv. type FAS?

1810


WE HAVE THE DC RECTIFIER 1500A, INPUT VOLTAGE IS 3 PHASE. HOW TO CALICULATE THE LOAD? 3 PHASE SIDE EITHER dC SIDE. PLEASE SUGGEST ME

1866


A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.

1933


how to check three phase motor torque value?

2352


how we calculate the short circuit capacity of the busbar in LV & HT?

1090




2388


Why space heater is required for each verical bus bar chamber? if one space heater is adequate or not for anti condensation?

2518


can we choose current transformer secondary, to calculate residual flux in a power transformer, so as its saturation is close to the saturation level of power transformer?

1470


list the advantages of RCCB over other circuit breakers?

1695


what happens to the water pump if ground water level is slowly decreasing?our water pump is varying from no-load full-load due to this problem

1651


what is the role of energy meter in distribution system ?

1164


What is the meaning of Insulation H for transformers????

2114


What is resolution of a measurement?

1181


-What should be minimum value of insulation resistance and maximum value of earth resistance at any electrical instillation and what is method of testing the same.

2070


why using transformer and thyristor switch in 3 phase apfc panel

2860