How to capture dynamic values in load runner and how Each
of the captured values are to be written to a text file
(c:\temp\LoadRunner1.txt)
Answer Posted / vaibhav kumar brijpuria
If you want to capture dynamic values which is returned by
server then in that case you need to do manual correlation,
and for doing manual correlation you need to find out the
boundaries(left as well as right) under which that dynamic
value is returned by server and then add a new
web_reg_save_param function along with correct left and
right boundaries to capture that value.
Regards,
Vaibhav
Is This Answer Correct ? | 9 Yes | 6 No |