In Fluorescent tube there is a writing like 6500k . what
this 6500k represents?
Answer Posted / sagar
It's colour temperature.
there is different different temperature for different colour.
6500k is means 6500 kelvin colour temperature of lighting.
6500k in the lighting is daylight source(cool white colour)
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses? the second question is-generation is depends on LV winding? or LV winding design for generation voltage?
What is the formula to calculate the rating of power cable for three phase current.
What is EMC filter in VVVF Drive ?
Why neutral point is consider as zero potential?
Can we use BS 6651 and BS EN 62305 standards for computer room lightning ptotection in substation?
What is different type of Electrical curve and how it protects the equipment's while up-normal situation?
H.t motor 6600 volt to same motor lt supply 440volt supply applyed to h.t motor to effect....
explain different losses in a transformer.
can anyone please help me to find the rupturing or breaking capacity in KA of circuit breaker (MCCB,VCB,ACB etc) of HT and LT side of a distribution transformer...please help with detailed step by step answer...thank you
Explain Need of a starter in a dc motor.? Also explain any two starting and speed control method of dc motor?
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
How PSV sizing being done
How to measure power in 2 or 4 or n phase circuit? Please give me a formula.
i have faced a problem in ro plant grunfos make bm30type pump it is 22kw pump. We start this pump using siemens 3rw 4423-ibc44, 30kw softstarter but this soft starter will frequently failier so we planed to change dol starter. So pls tell anybudy its possible or not.
can some one clearly explain why -48 volt DC use in telecom site????