Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How do you think they do earthing or grounding in ships and
aeroplanes?

Answer Posted / bimal

ONboard ship they use insulated neutral system ie the neutral is not having a 4th cable thats grounds it.hence the distribution system is 3 phase 3 wire system instead of 3 ph 4 wire as in shore systems

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Define reserve-generating capacity?

1240


I am shobana from Chennai. I am having my personal interview on 19th Dec at Chennai.kindly mail me the questions to mail id shobana.shanthi@gmail.com

2425


Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?

2178


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2198


Pls explan the OLR setting in VCB at HT yard

2740


why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.

2206


what type of motor used to move a 1 ton gate? and relate ratings with load.

1867


If Neutral Grounding Resistor (GR) failed/shorted. Is it repairable.

1685


How to improve fuel cell in a distribution system?

2046


why i can not use thimble on capacitor duty contactor

1400


What is the formula to calculate a three phase alternator

2391


Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.

2559


Draw the vector diagram and condition for the following: 1) Dyn1 2) Ynd0 3) YnYn0

3732


Draw the single line diagram of the power station?

1140


howmany electrician should maintain for a 1000 kva used plant... in kerala..

2158