Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why is used for starters for staring motors?

Answer Posted / priya

Starters are used to limit high currents during starting by adding resistors in series with armature circuit which are excluded gradually when the motor speed increases. High starting currents are due to
1. In case of DC motor, initially back emf(E) is zero therefore I=(V-E)/Ra becomes V/Ra. Generally Ra armature circuit resistance is very low hence I is very high during starting. When speed increases back emf increases and I reduces therefore resistors can be excluded.
2. In synchronous motors starters are not used

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the easiest method of short circuit current calculation ? pls. derive with a mathematical example in real life application.

2480


What happens when two positively charged material is placed together?

1190


What is the exact formula for one weber of magnetic flux?

2175


What is the difference between a Root Locus plot and a Bode plot?

1336


What is the function of under voltage release ?

1495


how can we calculate the ratio of caustic soda and water in lrs.

5898


how unidirectional torque is produced in DC motor?

6837


Disadventage of cable-gland earthing if any ?

2310


why ct's&pt'S out put called as burden,why compelsary short ckt the secondary of ct's while removing the burden?

2372


EXPLIAN THE IMPORTANCE OF POLY PHASE CIRCUIT.

2228


WHY NUTRAL GROUND SYSTEM USED IN 33KV SYSTEM

2255


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1979


What will be the effect if I use inverter as UPS mood?

2242


ult of expression 'document.FrmQF.myem

2130


In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.