I want to measure flow by using DP Tx and range is 0 to 1200 Kg/cm2 ?

Answer Posted / haridass

My dear Sam, the question submitter may be new for the
instrumentation, plz dont discourage him or the people who
ask like this type of questions.

My dear friend Mayur.kevadiya, the DP range of the flow
transmitter will not be with this much ranged values, it
will be in 0~100inWC, 0-2500mmWC, 0~100mbar, 0~200kPa such
like low ranges.

And only with the DP range we can not say the line flow, to
find that we need more data, such as, line size, orifice
bore dia, line pressure, flow density, flow coefficient,
etc.

Refer the link for more details:
http://www.efunda.com/formulae/fluids/calc_orifice_flowmeter
.cfm

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What should be the main consideration while starting the Rotating compressor when we dont know the cut in and the cut off pressure setting of the pressure switch

1698


draw shematic diagram of c/v positioner(smart type)?

1757


what is output of FOUNDATION FIELD BUS transmitter

1694


what is the difference between active & reactive power?

1666


how u choose thermowell lenght n pnumatic C/v size?

1670






What is PDS and PDMS ?

1695


How to calibrate smoke Dectector

1128


What are the type of bonnets in the control valves?

1418


What is Erosion in a control valve?

1561


Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability

1392


how can leve transmetter calibate in feild .and also put cv and flow plz .....

1770


Isometric drawings are generated during _________________ phase of a project

1610


Which is the best field foundation bus. ( FF ) Yokogawa, Honeywell or others ?

1347


What denotes the 5/8mm in the 3300XL 5/8mm proximitor probe?

983


Why we are using reverse action in displacer types level transmitters on some Vessels?

2031