why transmission line 11Kv OR 33KV,66Kv not in 10kv 20kv?
Answer Posted / ami wald
This Asia standard taken from previous British Commenwealth Countries.
In Continent Europe which has strong industry and different view on everything including Electricity, because the Electricity was born here we have another standard and over voltage levels. We forgot all not industrial time electricity for standardization and we use first 50 Hz (cycles) and voltages as 1100 kV, 750 kV, 500 kV, 400 kV, 220kV, 110 kV, 30 kV for cast iron furnaces only, 20 kV, 15 kV, 10kV for big motors above 250 kWatts only, 6kV for compressors and big motors only, and 0,660 kV , 400 Volts and 230 Volts at homes. US using for lighting in high rise buildings 277 Volts;
These voltages have been standardized in all United Europe. Another voltages are outside of Europe used in non-industriialised countries. So if the India want to take grow in industry it shall follow the European Union rules. and stop to use 33kV 22kV, 11kV, becasue these voltages are not typical and they are manufactured on individual request. It means they are more costly.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is non-minimum phase transfer function?
what is submersible pump?what is different between motor and sub motor?
how many single tension hardware are required on a double circuit transmission tower?
Explain and give me an example of a time when you had to explain some new procedures to your co-workers for quality service delivery, how did you go about it?
Give accurate definitions for these electric terms: Inductor Inductance Inductive Induction Reactance Reactive Esam Baraka ٢١ ساعة
how to find out 3 phase complex power in per unit in unbalanced system?
Name the component u would expect to find in a switchgear assembly?
Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example?
Why do we require transformer with less specific weight if supply frequency is increased?
Can we use BS 6651 and BS EN 62305 standards for computer room lightning ptotection in substation?
how does this job compare with others you have aplied for?
For a 6.6kV Motor it is recommended to do megger test with 500 V d.c and not more than 5kV d.c but the Hi voltage withstand test should be performed by 12kV AC. Why the dc voltage test should be limited but AC voltage withstand test could be with such a high voltage?
how to remover corona effect and hysteresis losses from contactor
relation between power station capacity and voltage level?
What is EHT tariff or Power factor Tariff ????