is tree is a good conductor and it may be used for conductor?
Answer Posted / abdul basit
tree is not a conductor, according to the definition of
conductor. But in case lightening current may pass from it
due to LARGE POTENTIAL. Secondly if a gtransmission line
fall on it then it would act as an ground and Line to
Ground case occurs.
CONCLUSION:
Not a GOOD Conductor, but can afect the power system system
due to its natural behaviu=our(construction)
| Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
Why insulation level follows this order? transformer < bus bar < circuit breaker & Isolator < transmission line.
If 22 KV HT line, Current transformer is 25/5 then how to calculate multiplying factor.
Between educational qualification and practical work experience, give us a brief explanation on your practical experience in your past Endeavour that you performed well to the satisfaction of your past or present employer?
sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.
after how many spot we must chang secondry cable in portable spot welding gun?
HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.
Hello sir i m student of gtu .what is idp.
What is the permissable nutral current of three phase system as per IS standards?
What is the difference between circuit breaker and isolator
Do closed loops systems require manual input?
what is difference between cpp electrical system and refinery electrical system
I have a relay contact rated at 220v dc which is supplied with a 24vdc from the panel,for it to trip the dampers(24vdc).What if the application of the relay changes so that it should work at its rated 220vdc then will it work at 24vdc supply given or any other consideration needs to be taken .....
either water sensor or flow meter,how we observe the water level, f any other equipment are in market ?
how can maintain the power factor and why and this is how do work tell us
What does ampere turns shows?