why is fan rotating slow speed, what is the problem?
Answer Posted / guest
In 3ph motor three winding are 120°electrical apart but in case of capactor motor. 1) phase spliti 90°by capacitor ie. 3/4 of NS. 2) generdly Poles are more than 3ph motor. these are may why capacitor fan run siow.
Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
what is the affect of earth's magnetic field on the frequency used in aircraft???
what is effect of 5amp fuse on 2mva pry protection of transformer
WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.
WE ARE PLACE A NEW 75 KW MOTOR FOR JPF.IT IS CONNECTED IN M.C.C. WHEN WE ARE STARTING M.C.C.INCOMER IS TRIPPED.THEN WE ARE CONNECTED IN P.C.C WITH A MM30 RELAY PROTECTION THEN WE ARE STARTED MOTOR WILL RUN SMOOTHLY.
wat is meant by PX class in ct?
CBCT selection
i have a 1500kVA transformer what is the kWH meter i need to use?
What are the major reasons for balancing hydro-thermal mix?
why d.c produces corrosion
What are the Return ( Monthly / quarterly/ Annual submitted to Electical Inspector for an establishment (Factory in Maharashtra-- Small scale category having seperate HT line of 22KV ) as per Maharashtra Electricity Act
sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance
what is transformor oil gread
define the non synchoronism of synchoronous machine in general g or m??
I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)
Why we use mho Relay in long transmission line?