Answer Posted / priyabrata
Anti pumping relay is nothing but it works as a protecting
device for close coil.It protects close coil for instants
operation when close command goes to breaker.Once breaker
get close comand it close but after closing if breaker gets
close command then anti pumping contactor prevents that.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What happen to generator if i have unbalanced load?
What is vaccum currcuit breaker.define with cause and where be use it device?
why high speed tripping relay will be used in tripping circuit why not normal relay
what is the role and fuction of automatic transfer switch in rotary ups
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
if in 3-phase system voltage=440V,frequency=60Hz, current=400A. then if it is single phase then current=? and if it is single phasing then current=?
"TRANSFORMER MODELING AND ANALYSIS" MEANS WHAT AND WHICH TOPICS U READ IN THIS
When semiconductor fuse does save thyristor in each cycle of conduction? Why under voltage setting keep less in SPRS and more in DC drive?
we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan
Discribe type of fault in DOL and stardelta startor.
At what speed an electric car can run with 2 HP motor of weighing 400 kg?
calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.
How can we decide cable size from HT panel to Transformer? Please give you reply with some examples.
hello friends this is krunal here.. i have applied for he officer train in hpcl electrical stream.. any one who have applied before for electrical stream please help me out.. post ur reply to my mail id: krunal_airforce@yahoo.com.. any tips, old questions for paper or any help will do.. plz help me.. your faithfully, Krunal Darji
how cables go in and come out for distribution from the feeder pillar box?