wat is the difference between real power and reactive
power..which is useful..?and how it s useful..wat is the
effect of these on a power system...
Answer Posted / saad
Active power
Which iz doing the real work lighting heating etc
Reactive power
Which iz used for the magnetizing of motors,transformers
and generators coils.
active power iz use ful but with out reactive power u never
magnetize any motor transformer or generator u can just
only improve the power factor to reduce ur loss.
KVA * PF = KW
for example
100 * 1 = 100 KW
IF pf 0.8
100*.8= 80KW
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
in parallel operation of power transformer why the distance between power transformer and capacitor bank feeder is necessary to know
i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value
Who are the manufacturer for Nitrogen based Fire Protectio/explosion prevention for Oil Filled Transformers? India and international both?
distribution is maximum done by a)radial b)network c) parallel d)b & c
Which cable is use for rtcc control panel
Why we use auxillary relay ? what is function of differential relay, directional o/c relay?
WHAT IS THE WORKING PRINCIPLE OF A GENERATER.how is a GTG (Gas TURBANE Generater) working.plz explane
how test transfomer(3 phase75kva) by megger
What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?
advantages and disadvantages of inverse definite minimum time RELAY
why actual valve timing diagram is different than ideal valve timing digram of a 4 stroke engine?
before transformer oil dielectric strenght tests are taken the oil should be allowed to settle to remove option 1 air bubbles 2 gasses 3 contamination 4 water
How to select circuit breakers rating eg. if i select a circuit breakers of capacity 40 amps DC with operating voltage 28 volts and if i what to use same circuit breakers for 300 Volts DC application what is the current rating of this circuit breakers.
What should be the magnetic balance test values for a 3 phase delta/star connected single primary dual secondary winding transformer (90 MVA / 2 X 45 MVA TRANSFORMER)
Why using synchronising methed in DG's sets?