Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are differences between Conventional & Addressable type
smoke detectors?

Answer Posted / raj

There are several differences between conventional &
addressable fire alarm systems. These differences include;
Addressable fire alarm systems give information about
individual detectors, whereas conventional systems only give
information
about specific circuits (zones).
1.
Due to this, addressable systems allow a courtesy text label
to allow easy identification of any event. For instance
detector 1
may be given the label “Bedroom 1.
2.
Most addressable systems allow an early “pre-alarm” warning,
which allows the responsible person to investigate potential
alarms before the system activates it`s sirens
3.
Many addressable systems can alter the alarm threshold of
the detectors, in order to meet the needs of different
environments in
different areas of the system
4.
5. Addressable systems are usually wired in a loop.
Conventional systems are usually wired as radial circuits.
6. Addressable systems usually have a real time clock &
event log to record system events.
Larger addressable systems usually have the ability to use
sophisticated programming options to operate certain outputs
only
with specific events.
7.
Historically, addressable systems have tended to be
complicated to configure, and cost between 50% to 100% more
than a
conventional equivalent

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the different between conventional MCC and intelligent MCC? Common controller or controller for each bucket

1052


how technical is calculated in 11kv line and lt line

2030


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1574


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2209


Why front mounted CT polarities are always towards breaker?

2013


explanation of mesh bus bars

2150


what is the diference between the 4pole & 6pole DC Motors & what is advantage 6pole over the 4pole ?

1993


What is the permissable nutral current of three phase system as per IS standards?

2086


if i get a drop in my 1st year and the i clear my 2nd year and 3rd year all clear and i dont have any back logs so can i be able to sit in campus selection??

1837


I had applied for JE in PSEB, Can you pls send me the Question bank for related to my field

1852


how to calculate single phase motor efficiency ?

2178


what is Anti-pumping?

1920


if any body have question paper of railway (section engineering),then plz send me .i will thank of him/her.

1982


how can i apilly for electrical c licencese.sir,i completed B.Tech in electrical & electronics engineering in 201onot working any company

1907


iam preparing for rrb section engineer post in electrical branch.suggest the right textbook for my reference.fromwhere i will get the previous q.papers?

2254