how we identify between current transformer and potential
transformer without having it name plate?
Answer Posted / mahaveer.r.d
To measure current in ckt, need to connect CT primary in
series with load. so terminal will be two per phase in/out.
To measure voltage, PT need to connect at across two phases
so no of terminals required at HT side one for each phase
so its essay to identify looking at no of terminals
| Is This Answer Correct ? | 1 Yes | 7 No |
Post New Answer View All Answers
how does a liquid starter reduce the starting currents?
What type of DC motor would you see for a lift?
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
why Lightening Arrester Probe sharp at Top of telecom tower.
How to find out damper winding failure for synchronous machine?
What happens to voltage when current is zero?
why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.
How do we calculate over and under frequency tolerance from generator data?
why does rotor rotets?
If I have Energy Meter Ratio as 100:5 & Also I have CT Ratio as 50:5 then what will be my multiplying Factor(M.F.)
I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?
2. Modify your design in question 1.a so that the circuit works according to the following function table X Y F 0 0 Clear 0 1 No Change 1 0 Parallel Loading 1 1 Count 3. Design a circuit that detects the pattern 010 in a serial input X considering: 3.a Overlapping 3.b No overlapping
We have received supplies of the ordered material. payments against the supplies also released. Where ST paid 4% against form C. Meanwhile it has been observed that 25% of material supplied was defective. Please suggest whether the issuance of C form from our side would be stopped till settlement of liabilities.
i have faced a problem in ro plant grunfos make bm30type pump it is 22kw pump. We start this pump using siemens 3rw 4423-ibc44, 30kw softstarter but this soft starter will frequently failier so we planed to change dol starter. So pls tell anybudy its possible or not.
what are the breakdown voltage rating of mini- curcuit'transfarmer!