Answer Posted / vin
(i) According to core,
1. Core type.
2. Shell type.
(a) Simple Shell,
(b) Distributed Shell.
(ii) According to winding.
1. Two winding (ordinary type).
2. Single winding (Auto type).
3. Three winding (Power transformer).
(iii) According to phase.
1. Single phase.
2. Three phase.
(iv) According to arrangement of coils.
1. Cylindrical type.
2. Disc type.
(v) According to use.
1. Power Transformers.
2. Distribution Transformers.
3. Instrument Transformers
(a) Current transformer,
(b) Potential transformer.
(vi) According to type of cooling
(a) Natural cooled.
(i) Natural air cooled.
(ii) Oil immersed natural cooled.
(iii) Oil immersed natural cooled with forced oil circulation.
(b) Forced air cooled.
(i) Oil immersed air blast cooled.
(ii) Oil immersed air blast cooled with forced air circulation.
(c) Water cooled.
(i) Oil immersed water cooled.
(ii) Oil immersed water cooled with forced oil circulation.
Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
Why use the vcb at high transmission system ? Why can’t use acb?
Why there are some equipment(i.e:TV) that using 2-pin plug instead of three? What happen if there is current leakage? Are we going to get electric shock??
1) why a dg set shows variation of power factor and load when synchronised with other dgs? 2)Why the load sharing is not become equal in all dgs?. 3)When a dg set will not run on auto start?
how to select correct size of power cable for inverter duty motor
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?
How to calculate the fuse rating depend upon the DC circuit?
How to calculate cable size in HT AND LT
plz tell me,ht and lt panel terminals in substations explain beiefly
When a single pase capacitor run motor- run on 230vac and Case(1)run with 8 Mfd 250 vac.capacitor , Case( 2) run with 8 Mfd 400vac capacitor. What is difference between both case regarding power ,efficiency etc?
What are the no-load losses for the 11000/415V transformer with the following rated capacity? 1.1500 kVA 2. 2000 kVA 3. 2500 kVA 4. 3000 kVA
how does a liquid starter reduce the starting currents?
HOW TO CALCULATE S/C,O/C,E/F OF ACB.
what are inherent currents?
We have 750KVA DG set, we want to introduce REF relay with 1250/1A,CL PS,Current transformers.The lead distance of 2.5mm copper flexible cable from CT to relay is around 5mtrs.We would like to know the knee point votage(VK) & IM calculion for CT's
What si the d/f b/w KVA & KWH, kvarh & kvar, kwh & kvar phase voltage & line voltage