Answer Posted / c r satpathy
The trip circuit supervision relay is used for supervising important control circuits such as circuit-breaker
and disconnector control circuits and signalling circuits in power electrical installations. Generally one supervision relay is needed per circuit to be supervised. If several branches of a circuit are to be supervised, the required
number of relays can be connected to the same control circuit. Continuous monitoring of circuit-breaker trip circuits and other essential control circuits. Preset operate time preventing unwanted alarm signals at circuit-breaker operation
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
how we control automatic generator i'e with to supply (main supply and local generator) when the main supply was break to supply the local supply automatically to begin supplying power.I now this control circuit is the combination of contactor time delay contactor switch and overload relay .but my question is how we combine those component thank you
What are the function of different components of servo motor?
why the projects getting loss?
What is the tests required for a 132 kV, 400 kV , 765 kV for a Circuit Breaker and Power Transformer before commissioning ?
how can i use REF and diffrencial relay both in 1 CT core for transformer protection?
hello!my name is sheikh iam preparing for indian engineering servieces,please send me the old question papers..to sheikhshaazforjobs@gmail.com
In case of generator when we consume more power produces by it why load on generator increase and starts sound more. and how it is adjusted..
HOW TO CALCULATE THE REGULATION OF 100 AND 25 KVA TRANSFORMER
what is conductor constant of raccun conductor
A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.
What is the formula to calculate the size of Aluminium and copper cable?
Difference between shunt, PMG and AREP excitation. Which is the most reliable between PMG and AREP.
Explain M Var? Which types of problem occurs when reactive power increase at the time of full load of plant and at the time of synchronize of plant?
In the Variable Voltage Variable Frequency Drive, how the Voltage and Frequency varied ? Is it varied in the Inverter part of the Drive ? Please give us supporting document if any.
What is difference between Harmonic and Non harmonic Capacitor Bank?