How the starter control the starting current in three
phase AC Motor?(In DC apply the reistance).
Answer Posted / ashli
induction motors are of two types- squirrel cage and phase
wound motors. in squirrel cage motor as the rotor
conductors are shorted by endrings its not possible to add
additional resistance.but we can limit the current by
reducing the supply voltage at starting. here the high
current inrush is limited by star-delta starter.ie at the
instant of starting the stator winding is connected in star
der by voltage per phase becomes V/(3)^.5.. after the rotor
attains sufficient speed the stator windind is made delta.
in phase wound type motor the rotor condutors are shorted
through resistors. and current is limited by applying
resistors
synchronous motor is not a self starting one. syn motor is
made to rotate at syn speed firstly only then 3 p supply is
given to the armature. so no question of high current arises
| Is This Answer Correct ? | 26 Yes | 5 No |
Post New Answer View All Answers
how to convert lv line to hv line and viseversa, any losses will occur during this process
How isolater function when installed inelectrical 440V wiring
explain me the relation between torque, frequency,speed,voltage and current in the 3 phase induction motor?
What is The Resistance Formula
what is the difference between fault current ant short circuit current?
what is the differences between microprocessor and general purpose computer
what is the relationship between phase & neutral
Purpose of providing neutral isolation panel for parallel operation of diesel generator
Why reactive power is needed in a power system? How is it being absorbed or delivered by alternators? For reactive power control we are changing excitation but reactive power absorbing or delivering related to stator. How these two are interlinked? i want a detailed explanation with necessary expressions and figures?
Explain the functioning of diode?
why all the feeders are designed in a particular manner ... is there any reason for that???
how to check avr of dg set of 125kva
I have a small system with two motors that are running on 380 vac, 60 hz. These motors are expensive and I usally get them from Brazil. I am adding another motor to the system, but I want to purchase a 480 vac, 60 hz motor to use. It will be on a VFD that is rated fro 380 thru 480. Is this posible and will I have to use a larger motor and derate it?
Why line VTG = √3 phase VTG in star? How?
what will be project cost for 100 kv transformer connection under oyt scheme.