1. What is the difference between ac induction motor
and ac synchronous motor?
Answer Posted / sumit patel
one can get the full detail from the above answers.
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
Discribe type of fault in DOL and stardelta startor.
How can eliminate noise problem inside temperature controller temp. variation due to contactor chattering problem.
WE know that for Inductor X=2pifL,In DC f=0,then X=0 so,V=IX=0;But In the DC excitation of rotor of AC generator,DC motor field coil which coils are inductor so why does not applying DC voltage short the rotor coil of AC generator and field coil of motor?If it would then DC source might be damaged but it is not happened. Why does the strand conductor of Electrical power transmission line make twist?
What is Plank's Law?
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
hello if any one have papers vof hpcl or sail, plz send me
What is the purpose of stand by earth fault protection for transformer ?
What do you mean by Frame 5 Gas Turbine as well as Mark II.
I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?
Should power factor be low or high?
What is hipot test procedure?
please I wont know how to calculate the vector group for power transformer ZNyn11 best regard.
What is the method of estamating of cable, CB,MCB ?
How can find thermal state value in relay for calculate thermal overload.