Answer Posted / rajesh
MATLAB (matrix laboratory) is a numerical computing
environment and fourth-generation programming language.
Developed by MathWorks, MATLAB allows matrix manipulations,
plotting of functions and data, implementation of
algorithms, creation of user interfaces, and interfacing
with programs written in other languages, including C, C++,
Java, and Fortran.
Although MATLAB is intended primarily for numerical
computing, an optional toolbox uses the MuPAD symbolic
engine, allowing access to symbolic computing capabilities.
An additional package, Simulink, adds graphical multi-domain
simulation and Model-Based Design for dynamic and embedded
systems.
| Is This Answer Correct ? | 3 Yes | 1 No |
Post New Answer View All Answers
what are procedure of sox-nox calibration
what is span value and zero ? and how set ?
Make Heater Process Logic.
What is force balance principle? State some of its’ advantages.
control panel design guidelines
give me the formula for analog to digital converter and also d to a converter
What is the diffrence between digital signal processing and discrete signal processing?
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
, Instrument Index, P&ID review, I/O schedule, datasheet, DCS / Analyzers specifications, loop diagrams, hook-up drawings.
Why do we floating DC in DC system.
How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.
Why are the uses 24vdc in industries
sir, give me placement papers and interview quistion of birla group company of copper.
what is interface level and how it is calibrate?
can u plz send me technical questions asked in SCHNEIDER ELECTRICAL technical paper?